The maximum voltage (AC or DC) that can be continuously applied between isolated circuits without a breakdown occurring.

BS EN 54 A standard forfire detection and fire alarm systems.

BS EN 60204 A standard forthe electrical equipment of machines, which promotes the safety of persons and property, consistency of control response and ease of maintenance.

bus A group of conductors which carry related data. Typically allocated to address, data and control functions in a microprocessor-based system.

bus arbitration A mechanism for deciding which device has control of a bus.

CIP Common Industrial Protocol. A communications protocol, formally known as ‘CIP™ over Ethernet/IP™’, created by Rockwell Automation for the Logix controller family, and which is also supported by the AADvance controller. AADvance controllers use the protocol to exchange data with Logix controllers. The data exchange uses a consumer/producer model.

clearance The shortest distance in air between two conductive parts.

coding peg A polarization key, fitted to the T9100 processor base unit and to each termination assembly, which verifies that only a module of the correct type may be fitted in a particular slot. Part number T9903.

coil In IEC 61131-3, a graphical component of a Ladder Diagram program, which represents the assignment of an output variable. In MODBUS language, a discrete output value.ICS TRIPLEX T9110 - Industrial Control Module

Compiler Verification Tool (CVT) An automatic software utility that validates the output of the application compilation process

configuration A grouping of all the application software and settings for a particular AADvance controller. The grouping must have a ‘target’, but for an AADvance controller it can have only one ‘resource’.

consumer The consuming controllerrequests the tag from the producing controller.

contact A graphical component of a Ladder Diagram program, which represents the status of an input variable.

continuous mode Where the Safety Instrumented Function in the Safety System is continually maintaining the process in a safe state.

controller A logic solver; the combination of application execution engine and I/O hardware.

controller system One or more controllers, their power sources, communications networks and computers.

coverage The percentage of faults that will be detected by automated diagnostics. See also ‘SFF’.

creepage distance The shortest distance along the surface of an insulating material between two conductive parts.

cross reference Information calculated by the AADvance® Workbench software or AADvance®- Trusted® SIS Workstation software relating to the dictionary of variables and where those variables are used in a project.

D

data access (DA) An OPC data type that provides real-time data from AADvance controllers to OPC clients.

de-energize to action A safety instrumented function circuit where the devices are energized under normal operation. Removal of power de-activates the field devices.

dictionary The set of internal input and output variables and defined words used in a program.

discrepancy A condition that exists if one or more of the elements disagree.

DITA Digital input termination assembly.

DOTA Digital output termination assembly.

E

element A set of input conditioning, application processing and output conditioning.

energize to action A safety instrumented function circuit where the outputs and devices are deenergized under normal operation. Application of power activates the field device.

EUC Equipment Under Control. The machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

expansion cable assembly A flexible interconnection carrying bus signals and power supplies between AADvance base units, available in a variety of lengths. Used in conjunction with a cable socket assembly (at the left hand side of a base unit) and a cable plug assembly (at the right hand side of a base unit).

F

fail operational state A state in which the fault has been masked. See ‘fault tolerant’.

fail safe The capability to go to a pre-determined safe state in the event of a specific malfunction.

fault reset button The momentary action push switch located on the front panel of the T9110 processor module.

fault tolerance Built-in capability of a system to provide continued correct execution of its assigned function in the presence of a limited number of hardware and software faults.

fault tolerant The capability to accept the effect of a single arbitrary fault and continue correct operation.

fault warning receiving station A centre from which the necessary corrective measures can be initiated.

fault warning routing equipment Intermediate equipment which routes a fault warning signal from the control and indicating equipment to a fault warning receiving station.

field device Item of equipment connected to the field side of the I/O terminals. Such equipment includes field wiring, sensors, final control elements and those operator interface devices hard-wired to I/O terminals.

fire alarm device A component of a fire alarm system, not incorporated in the control and indicating equipment which is used to give a warning of fire — for example a sounder or visual indicator.

fire alarm receiving station A centre from which the necessary fire protection orfire fighting measures can be initiated at any time.

fire alarm routing equipment Intermediate equipment which routes an alarm signal from control and indicating equipment to a fire alarm receiving station.

function block diagram An IEC 61131 language that describes a function between input variables and output variables. Input and output variables are connected to blocks by connection lines. See ‘limited variability language’.

functional safety The ability of a system to carry out the actions necessary to achieve orto maintain a safe state forthe process and its associated equipment.
Related product recommendations:
ABB 07KT92 GJR5250500R0902
MOTOROLA MVME-147SA1
Emerson 12P4629X082
ABB 3ABD68232902
ABB 3HAC13056-3
Honeywell 51196694-901
ABB IRB 4600 33HAC039109-002
Siemens 3RW4423-1BC44
Emerson KJ3102X1-BA1
ABB HESG32401 3R0100216A-B61
B&R X20SL8000
SIEMENS 6ES7 193-4CB30-0AA0
More…